| Sign In | Join Free | My autochinanet.com | 
              
  | 
      
Brand Name : PEPPERL FUCHS
Model Number : RD0-FB-Ex4.*
Place of Origin : Germany
MOQ : 1
Price : Negotiable
Payment Terms : T/T
Supply Ability : 100pcs per month
Delivery Time : Negotiable
Packaging Details : carton
Manufacturer : PEPPERL FUCHS
Product No : RD0-FB-Ex4.*
Current : 248 mA
Fieldbus standard : IEC 61158-2
Rated voltage : 10 ... 13 V
Housing : see figure 1
Degree of protection : IP20
Mass : 1050 g
Pepperl Fuchs Fieldbus Barrier RD0-FB-Ex4.*
 4 outputs Ex ia IIC
 FieldBarrier in Zone 1/Div. 2
 Instruments in Zone 0...1/Div. 1
 Short circuit current limitation per output
 For FOUNDATION Fieldbus H1 and PROFIBUS PA
 Power, Com, and Error LEDs
 Supports FISCO and Entity
 Integrated cable tie-downs
 Supports all grounding methods
 General specifications
 Fieldbus barrier, module for DIN rail mounting
 General specifications
 Design / Mounting    Cabinet installation
 Installation in hazardous area    Zone 1 / Div. 2
 Fieldbus connection
 Main cable (Trunk)    
 Connection    input (Trunk IN): terminals 3+, 4-, 5s
 output (Trunk OUT): terminals 7-, 8+, 6s
 Rated voltage    32 ... 16 V DC
 Rated current    31 mA ... 26 mA (without load)
 77 mA ... 115 mA (at 20 mA load per input)
 120 mA ... 209 mA (at 40 mA load per input)
 135 mA ... 241 mA (short-circuit on all outputs)
 Voltage drop    trunk IN to trunk OUT 100 mV max.
 Number of couplers    max. 4 per segment
 Outputs    
 Number of devices per output    1
 Connection    output 1: terminals 10+, 11-, 12S shield;
 output 2: terminals 13+, 14-, 15S shield;
 output 3: terminals 16+, 17-, 18S shield;
 output 4: terminals 19+, 20-, 21S shield
 Rated voltage    10 ... 13 V
 Rated current    max. 43 mA
 Short-circuit current    50 mA
 Indicators/operating means
 LED voltage Fieldbus    green: on, bus voltage existent
 LED status output    red flashing: short-circuit
 Galvanic isolation
 Main wire/outputs    isolation is not affected by interference according to EN 50020, voltage peak value 375 V
 Directive conformity
 Electromagnetic compatibility    
 Directive 2014/30/EU    EN 61326-1:2013
 Standard conformity
 Electromagnetic compatibility    NE 21:2006
 Degree of protection    IEC/EN 60529
 Fieldbus standard    IEC 61158-2
 Climatic conditions    DIN IEC 721
 Corrosion resistance    acc. to ISA-S71.04-1985, severity level G3
 Ambient conditions
 Ambient temperature    -50 ... 70 °C (-58 ... 158 °F)
 Storage temperature    -40 ... 85 °C (-40 ... 185 °F)
 Mechanical specifications
 Connection type    screw terminal
 Core cross section    up to 2.5 mm2
 Housing    see figure 1
 Housing material    Polycarbonate
 R... DIN rail housing    PA 6.6
 Degree of protection    IP20
 Mass    1050 g
 Mounting    DIN rail mounting
 Data for application in connection with hazardous areas
 EU-type examination certificate    PTB 02 ATEX 2086
 Marking    Ex-Hexagon II 2 (1) G Ex eb mb [ia Ga] IIC T4 Gb ,
 Ex-Hexagon II (1) D [Ex ia Da] IIIC
 Main cable (Trunk)    
 Maximum safe voltage Um    253 V AC
 Outputs    
 Power    975 mW
 Voltage    15.75 V
 Current    248 mA
 Directive conformity    
 Directive 2014/34/EU    EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN 60079-18:2015+A1:2017
 International approvals
 FM approval    CoC 3015728
 Control drawing    116-0266
 Approved for    Class I, Division 2, Groups A, B, C, D / Class I, Zone 2, AEx nA [ia] IIC T4
 CSA approval    CoC 1845315
 Control drawing    116-0266
 Approved for    Class I, Division 2, Groups A, B, C, D / Class I, Zone 2, Ex nA [ia] IIC T4
 IECEx approval    IECEx PTB 03.0003
 Approved for    Ex eb mb [ia Ga] IIC T4 Gb , [Ex ia Da] IIIC
 Certificates and approvals
 FOUNDATION Fieldbus    FF-846
 Marine approval    DNV A-14038
 
 
 
 
 
 
 
 
 
 
 
 
  
| 
                                             | 
                
                        Pepperl Fuchs Fieldbus Barrier RD0-FB-Ex4.* Integrated Cable Tie-Downs Images |